DrägerSensor EC Electrochemical Sensors
Faster response – higher accuracy – greater stability – longer life. Dräger electrochemical sensors offer all these benefits. The robust and long-life sensors are used for the selective measurement of the smallest concentrations of toxic gases and oxygen in ambient air.

Product features
- Long life time
- The use of resistant plastics, such as TEFLON, and the purest catalysts make it possible to achieve a long, wear-free measurement function over long periods. A patented internal pressure compensation mechanism compensates adverse environmental influences from changes in humidity, temperature expansion and weather-related variations in air pressure. A large electrolytic reservoir and large electrode areas provide sufficient reserves for a long life time, even in industrial environments.
- Ready for use immediately
- All sensors are factory calibrated, and these values are saved in the internal, electronic memory. This means that sensors in the field can be used immediately. The high-quality technical construction guarantees a long stability and low, age-related drift.
- Comprehensive range of applications
- All sensors have an internal temperature sensor. Between -40°C and +65°C, the temperature influence is compensated to zero, and the sensitivity is automatically adjusted. The internal pressure compensation allows the transmitters to be used during extreme low pressure, and high atmospheric pressure. In combination with exchangeable, selective filters, it is possible to reduce the influence of disruptive cross-sensitivities.
- Advanced sensor technology
-
- It is possible to choose between oxygen sensors for partial pressure measurement or volume percent measurement.
- Acid gas sensor AC with unlimited life time, due to refillable electrolyte.
- Sensors with organic electrolyte for detection limits in lower ppb range.
- Performance
-
- Low detection limits
- Optimised selectivity
- Excellent accuracy of measurements
- Fast response
- High stability
- Wide range of applicational areas
- Long life time
- Comprehensive self-diagnosis options
- No position dependency
Product Information
DrägerSensor CO carbon monoxide
DrägerSensor CO LS carbon monoxide (long-term stability)
DrägerSensor H2S LC hydrogen sulfide and mercaptans (low concentration)
Dräger H2S HC hydrogen sulfide (high concentration)
DrägerSensor H2S hydrogen sulfide
DrägerSensor® OV 1
DrägerSensor® OV 2
DrägerSensor® H2
DrägerSensor® NO2
DrägerSensor® NO
DrägerSensor® HCN
DrägerSensor® SO2
DrägerSensor® O2 LS
DrägerSensor® O2
DrägerSensor® H2O2 LC
DrägerSensor® H2O2 HC
DrägerSensor® NH3 LC
DrägerSensor® NH3 HC
DrägerSensor® HCl
Dräger Sensor AC
Dräger Sensor Hydrazine
Dräger Sensor Hydride
Dräger Sensor PH3/AsH3
Sensor Hydride SC
Dräger Sensor XS NF3
Dräger Sensor O3
Dräger Sensor XS PFC
Dräger Sensor COCI2
Accessories
Gassing adapter
Hard PE adapter for gassing of electrochemical sensors in Dräger Transmitters during calibration. Also suitable for continuous gassing, when used with a pump.
Order No.: 68 06 978

Viton calibration adapter
Soft adapter, made of Viton, for gassing during zero point test and when calibrating electrochemical sensors in Dräger Transmitters.
Order No.: 68 10 536

Remote calibration adapter
For calibrations in transmitters with electrochemical sensors, which are positioned in areas with restricted access
Order No.: 68 07 955

Calibration bottle
A plastic, 3-litre container for generating a defined concentration of gas, using test gas ampoules, when calibrating electrochemical sensors.
Order No.: 68 03 407

Dust filter
Hydrophobic dust filter for electrochemical polytron sensors (see also the corresponding sensor data specification).
Order No.: 68 09 595

Start up kit AC, AC L and HF/HCI L
For filling of sensors (Part No. 6809375, 6810595) and Dräger Polytron HF/HCl L (Part No. 6809360), consisting of bottles with electrolyte and pipette.
Order No.: 68 09 381

Test gas ampoules
For use with the calibration bottle. Test gas ampoules are available for the following gases/concentrations:
68 07 763 Test gas ampoule SO2 10 ppm
68 07 764 Test gas ampoule SO2 50 ppm
68 07 765 Test gas ampoule NO2 10 ppm
68 07 766 Test gas ampoule NO2 50 ppm
68 07 920 Test gas ampoule CO 100 ppm
68 07 921 Test gas ampoule CO 300 ppm
68 07 923 Test gas ampoule NH3 300 ppm
68 07 924 Test gas ampoule NH3 50 ppm
68 07 925 Test gas ampoule SO2 1 ppm
68 07 926 Test gas ampoule SO2 4 ppm
68 07 928 Test gas ampoule Cl2 8 ppm
68 07 929 Test gas ampoule HCN 10 ppm
68 08 140 Test gas ampoule H2S 10 ppm
68 08 141 Test gas ampoule H2S 20 ppm
68 08 142 Test gas ampoule H2S 40 ppm
68 08 143 Test gas ampoule H2S 100 ppm

Selective filter
Selective filters absorb interfering gases from the ambient air. They are located in the sensor opening of the DrägerSensor and can easily be replaced if worn out.The following selective filters are available (see also the corresponding sensor data specification):
Selective filters for use with DrägerSensors:
CO (6809605) 6809684 A2F
CO LS (6809620) 6809684 A2F
COCI2 (6809930) 6809933 K2F
H2 (6809685) 6809684 A2F
HCI (6809640) 6809643 NF
HCN (6809650) 6809653 BF
Hydride (6809635) 6809658 CF
NO2 (6809655) 6809658 CF
PH3/AsH3 (6809695) 6809638 MF
SO2 (6809660) 6809663 KIF

Calibration/process adapter AC
Gassing adapter, suitable for calibration of DrägerSensor AC (Part No.: 6810595) and for continuous gassing when used with a pump.
Order No.: 68 09 380

Sensor test set HF/HCI L
Test set for generating an HCI test gas concentration for functional tests on the DrägerSensor AC and Dräger Polytron L HF/HCI
Order No's.:
Bottle 6808085
Chemical set 6808084

Splash guard
Protects the DrägerSensor AC (Part No.: 6810595) against dripping water.
Order No.: 68 09 379
System Components
The Dräger Polytron 7000 is an intrinsically safe gas detector for the continuous monitoring of toxic gasses and oxygen. With its unique modular design and total flexibility: The Dräger Polytron 7000 is a truly universal transmitter that can satisfy all toxic and oxygen measurement applications on a single platform. SIL 2 Approval guarantees no unrevealed failures.
The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of toxic gasses and oxygen. High measuring accuracy alongside simple mounting and very easy operation. The Polytron 3000 is ideally suited to the measuring of toxic gases and oxygen in a wide range of applications.
The Dräger Polytron 7500 is a pyrolysing gas detector for the continuous monitoring of toxic gases such as NF3 and perfluorinated C4F6 and C5F8 in the ambient air. The device contains all necessary functions such as sampling, processing and analysis in one enclosure.
The Dräger Polytron 2 XP Tox is an explosion proof gas detector for continuous monitoring of toxic gases and oxygen in ambient air. The transmitter converts the signal from an electrochemical sensor to 4 to 20 mA analog, HART® or RS 485 digital signal output. The unit is designed for one-man calibration, and offers a variety of diagnostics and self test features.
The Dräger Polytron TX is an explosion proof gas detector for continuous monitoring of toxic gases and oxygen in ambient air. Non-intrusive calibration and maintenance means no special area permits are required to perform routine tasks.
Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.
The Regard 3900 is a standalone, autonomous control system for up to 16 gas detectors. It is fully configurable and monitors the concentration of toxic gases, oxygen and combustible gases and vapours.
Whether they are mounted to a wall or integrated in the switch cabinet - the flexible small control units Regard 2400 and Regard 2410 reliably monitor the concentration of toxic gases and oxygen as well as combustible gases and vapours.
Robust, reliable and very cost effective. The compact Regard-1 is a complete standalone system for the control of a single gas detector; suitable for monitors of toxic gases, oxygen, combustible gases and vapours.
Related Products
Upgrade from Catalytic bead to infrared technology with ease using the DrägerSensor IR. The Sensor IR can replace catalytic ex-sensors (pellistors) from the majority of manufacturers without replacing controllers, cables, junction boxes or control systems.
The Dräger Catalytic Bead Sensors is designed for the continuous monitoring and detection of combustible gases and vapours – with different versions for different applications or concentrations.
Literature
List of detectable gases and vapours.
For over 70 years, Dräger has been one of the technology leaders in gas detection.
When there’s danger in the air ... this can quickly pose a high risk to humans, the environment, and all types of property and systems. Recognize the threat before it is too late.
Safety Instrumented Systems are used to reduce the risk for the protection of people, plants, and environment.
Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion protection measures it may be preferable to detect them before they become ignitable.
Slots follow
Web site search
Get in contact with us
Draeger Safety Pacific Pty Ltd
Axxess Corporate Park
Unit 99, 45 Gilby Road
VIC 3149 Mount Waverley
+1800 67 77 87
+1800 64 74 84
Contact us- How to find us?
-
Find worldwide locations of our service locations, distributors and others in our address search.
- Dräger Customer Service and Support
- Interlock Workshops
- Premium Distributors (for Occupational Safety Equipment)